Remote Nondestructive Testing of Unpiggable Pipelines

since 1999
  • Homepage in English
  • Homepage in Russian
  • Homepage in Spanish

DIRECTIONS for pipeline technical condition diagnostics by non-contact magnetometric method. RD 102-008-2002

DEVELOPED by:
Experts of oil and gas production facilities construction and operation center. Engineering oil-and-gas company – All-Russia Research Institute on pipeline and fuel and energy complex facilities construction and operation (AO VNIIST) (Moscow)

AUTHORS: AO VNIIST President
Ph.D. R.S. Gasparyants;
AO VNIIST vice-president
Ph.D. G.A. Giller;
Experts of oil and gas production facilities construction and operation center, Director

Ph.D. V.P. Goroshevskiy;
Head of Laboratory V.I. Grechishkin;
Head of Laboratory S.S. Kamaeva;
Chief research assistant
I.S. Kolesnikov;
Chief economist
Ph.D. (Physico-Mathematical Sciences) A.A. Maslov;
Chief engineer S.V. Khlopotov

CONFIRMED: AO VNIIST 09.10.2002.
COMMISSIONED:
FIRST
APPROVED:
GOSGORTEKHNADZOR of Russian Federation
Letter #10-03/1181 of 10.12.2002.

CONTENT:

  1. Purpose and scope
  2. Terms and definitions
  3. General Provisions, normative references
  4. Execution order of diagnostics inspection by the non-contact magnetometric method
  5. Drawing up the diagnostics inspection results
  6. Instrumentware recommended for complex inspection execution
  7. Security measures instructions

APPENDIX 1 (compulsory):
Submission form of the results of inspection executed by non-contact magnetometric method

APPENDIX 2 (recommended):
Technical data of the devices recommended for non-contact magnetometric inspection.

Purpose and scope

A management directive RD 102-008-2002 "Directions for pipeline technical condition diagnostics by non-contact magnetometric method” is a technical-organizational normative document which regulates ferromagnetic pipelines technical condition assessment at the facilities controlled by Gosgortekhnadzor of Russia. Facilities under diagnostics are as follows: oil-field and main pipelines of the Fuel and Energy Complex and of other sectors of industry which operate pipeline systems under pressure; municipal system gas-, hot-water-, water- supply pipelines; industrial pipelines, product pipelines. The information collected by the non-contact magnetometric diagnostics is the basis for residual life assessment and Decision issuing founded on industrial safety examination results.